Jaaj.sk je nový FREE porovnávač produktov a cien. Budujeme AI alternatívu ku klasickým porovnávačom

Spúšťame databázu
Produkty • kategórie • porovnania

Ubiquiti UniFi Access - G3 Reader čtečka karet (RFID 13,56MHz/NFC/mobil) černá

Základní čtečka G3 generace s funkcí Touch Pass support.Overview Dimensions93 x 40 x 36.5 mm NFC Card & Keyfob AccessYesApple/Google WalletYesMobile UnlockYesHandwave Request to ExitYesNDAA…

od 150 €

Specifikacia Ubiquiti UniFi Access - G3 Reader čtečka karet (RFID 13,56MHz/NFC/mobil) černá


Základní čtečka G3 generace s funkcí Touch Pass support.Overview Dimensions93 x 40 x 36.5 mm NFC Card & Keyfob AccessYesApple/Google WalletYesMobile UnlockYesHandwave Request to ExitYesNDAA CompliantYesUL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level IWeatherproofingIP55 Mechanical Weight82 g (2.9 oz)Enclosure MaterialPolycarbonate, glassMount MaterialAluminum alloyMountingIn-wall, gang box (Included) Junction box (Optional) Hardware Indoor and Outdoor UseYesAmbient Operating Temperature-30 to 45° C Ambient Operating Humidity5 to 90% noncondensingNetworking Interface(1) 10/100 MbE RJ45 portConnectivityBLE 4.1 NFCPower MethodPoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSUMax. Power Consumption5WSupported Voltage Range48V DCESD/EMP ProtectionAir: ±15kV, contact: ±8kVSensorsProximity sensorSpeakeryesLEDsR/G/B/WButton(1) Factory-resetNFC Frequency13.56 MHzNFC Read Range< 30 mm (1.18'')NFC TechnologyISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340) MIFARE Classic / MIFARE DESFIRE Sony FeliCa™ (ID only) NFC Forum tags T1T, T2T, T3T, T4T and T5T ECP 2.0PoE Cabling RequirementsCat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.CAN/ULC-60839-11-1 GradeGrade assignment: ICertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1Document number, and issue date and/or revision levelUA-G3, V01 Software Management ApplicationAccessSoftware InformationThe software version can be checked at https://unifi.ui.com

Top